UF membranes all modules
Performance | Modules | RM-UF-4040 | RM-UF-4021 | RM-UF-4046 | RM-UF-160B | RM-UF-8040 | RM-UF-8060 | RM-UF-1060 |
Picture | ||||||||
Material PAN / PS / PVDF | PAN / PS / PVDF | PAN / PS / PVDF | PAN / PS / PVDF | PAN / PS / PVDF | PAN / PS / PVDF | PAN / PS / PVDF | PAN | |
Size inch diameter x inch length | 4'' dia x 40'' | 4'' dia x 21'' | 4'' dia x 46'' | 6'' dia x 60'' | 8'' dia x 40'' | 8'' dia x 60'' | 10'' dia x 60'' | |
Molecular weight cutoff Dalton | 50,000 | 50,000 | 50,000 | 50,000 | 100,000 | 100,000 | 50,000 | |
Designed Permeate Flow L/m^2/H | 40~150 | 40~150 | 40~150 | 40~150 | 40~150 | 40~150 | 40~150 | |
Effective membrane area m^2 | 4 | 2 | 4.8 | 18 | 18 | 25 | 46 | |
Initial Permeate Flow m^3/H | 0.8 | 0.4 | 1 | 3.6 | 4 | 5 | 9 | |
No. of membrane filaments | 1,400 | 1,400 | 1,500 | 4,200 | 7,300 | 7,300 | 12,500 | |
bore diameter µm | 0.01-0.1 | 0.01-0.1 | 0.01-0.1 | 0.01-0.1 | 0.01-0.1 | 0.01-0.1 | 0.01-0.1 | |
Operating conditions | Max operating pressure psi (MPa) | 43(0.3) | ||||||
Suggested operating pressure psi (MPa) | 15(0.1) | |||||||
The maximum water supply temperature | 5~40°C | |||||||
The maximum water supply SDI | < 25 | |||||||
free chlorine concentration in water supply | <70ppm | |||||||
Water supply pH in running | 3~9 | |||||||
Water supply pH scope in chemical clean | 2~12 | |||||||
Feed water Turbidity NTU | < 1 |