NF(Nano-filtration) Membranes
Home / Products / NF(Nano-filtration) Membranes

NF(Nano-filtration) Membranes

Download
Brief Introduction

The NF Series of nanofiltration membrane elements can achieve high permeate water and excellent desalination performance. Therefore, it is suitable for large-scale industrial and municipal water treatment systems. In use, it shows excellent ability to remove pesticides, viruses, and bacteria. It has a high ability to remove natural organic substances and a medium ability to remove total hardness. Through innovative technology, the product has a stronger film surface, strong anti-oxidation performance, and the use of ultra-low pressure mode of operation can significantly improve the system and operational economy.

Scope of Application

It is mainly used in various ffelds of industry, such as pure water, boiler recharge water, food processing and pharmaceutical manufacturing.

  • NF series of membrane elements performance

Model

Membrane ft2 (m2)

Average Permeate GPD(m3/d)

Stable Rejection %

Min. Rejection %

RM-NF-4040

85 (7.9)

2200 (7.9)

55~75

-

RM-NF-8040

400 (37)

9000 (33.9)

55~75

-

 

  • NF series of membrane elements Testing Conditions

Testing Pressure

70 psi (0.48MPa)

Temperature of Testing Solution

25 ℃

Concentration of Testing Solution (NaCl)

2000ppm NaCl;2000ppm MgSO4

pH Value of Testing Solution

8

Recovery Rate of Single Element

15%

 

  • NF series of membrane elements Operation Limits & Conditions

Max. Working Pressure

600psi (4.14MPa)

Max. Feed Water COD

10ppm

Max. Feed Water Flow

75 gpm (17m3/h) for 8040
16 gpm (3.6m3/h) for 4040

Max. Feed Water BOD

5ppm

Max. Feed Water TOC

10ppm

Max. Feed Water Temperature

45°C

Residual Chlorine Concentration of Feed Water

<0.1 ppm

Max. Feed Water TDS

2000ppm

pH Range of Feed Water During Continuous Operation

3~10

ax. Feed Water Hardness

60ppm

Max. Pressure Drop of Single Element

15psi (0.1MPa) 8040、4040

Max. Feed Water SD 115

5

Max.Turbidity NTU

1.0

Note: 

1. For the recommended design scope, please refer to the latest version of the technical manual, design guide, or consult with membrane technology experts. If the user does not strictly follow the operating conditions provided by the sample, Suzhou Runmo Water Treatment Technology Co., Ltd. will not bear all the consequences arising therefrom.
2. The average water yield listed in the table shows that the error of water yield of a single membrane element in series is within (+10%).
The difference between the minimum water yield and the nominal value of other series of single membrane elements is not more than 20% of the nominal value.
3. Wet membrane components are strictly tested before they leave the factory. They are stored in 1.0% sodium bisulfite solution. Then they are packed in vacuum and packed in cardboard boxes. The safe storage temperature of wet membrane components is 4-45 °C.
4. RO production water to be discharged in the first hour of operation.
5. During storage and operation, it is prohibited to add any chemicals that affect membrane components. In case of violating the use of such chemicals, Suzhou Runmo Water Treatment Technology Co., Ltd. will not bear all the consequences arising therefrom.

CONTACT FORM